Clauses and design assumptions
Site assumption. One domestic tower on 36 × 32 m of private land beside a level 14 m street. We assume a single frontage on a government street maintained by the Highways Department. This gives Class A under reg. 18A(1), (3)(a)(i). The adjoining street is outside the 1,152 m² site. Reg. 26 concerns streets narrower than 4.5 m.
Density. Regs. 20(1)(a) and 21(1)(a) use First Schedule columns 2 and 5. Each proposed stack uses one row for its entire footprint and GFA. Reg. 23(1) measures from mean street level to mean roof height above the highest usable floor. Here the street datum and lowest floor coincide and the roof is flat. Plot ratio is GFA divided by site area under reg. 21(3). The model sums external plate areas under reg. 23(2) and (3)(a), with no balconies, basements, bonuses or deductions.
Rear open space. Reg. 25(1)(a), (b), (2) and Second Schedule item 1 require rear clearance and open space of at least half the roofed-over area. The model reserves it all in a full-width rear strip with at least 1.5 m clearance. The yard is assumed accessible and 150 mm below the lowest floor. Lane provision under reg. 28 is outside the study.
Rear windows. For a habitable room facing a site boundary, reg. 31(1)(d) projects an 80.5° plane towards the site at sill level. Reg. 31(3)(b) sets the reference sill 1 m above the room floor. This study assumes no rear lane and a 4.6 m sill base in a repeated window bay. It reserves at least 21 m² of clear horizontal plane, a 2.3 m minimum base and 2.3 m minimum boundary distance under reg. 31(1)(b), (2)(a), (b), (d). The amber strip shows the lowest window bay. Its section is repeated across the façade as a design choice. Reg. 31(1)(a) covers a window facing the 14 m street. The 71.5° same-site obstruction test in reg. 31(1)(c) is a different geometry. Room layouts, glazing and openable areas under reg. 30 are untested.
Massing and yield assumptions. Each storey is 3.1 m high. Plates stay 30 m wide, share a street edge and need 6 m depth to count. Both sliders above the rules are design choices. The solver tests every whole-building height up to the target and shows the tallest fit. The dashed plate belongs to the next candidate, with all its floors recalculated at its own height band. Homes are rounded down on each floor.
Zoning plans, lease limits, other Buildings Ordinance requirements and discretionary modifications need a real site assessment. Switching off a check shows a comparison. This massing study is illustrative.
Sources. HKSAR Government, Building (Planning) Regulations, Cap. 123F, consolidated version of 17 September 2026. Checked 13 November 2026. Hong Kong e-Legislation · Department of Justice text · Planning Department, chapter 2, table 4.