Method & assumptions
Five seeded form families share a 120 × 120 m parcel and 18,000 m² of gross floor area. The three ground measures sample the centres of 4 m cells outside the footprints. Each cell has equal weight.
Sun. Clear-sky equinox at 35° N, 08:00–16:00 solar time. Sixteen half-hour ray tests per cell against the massing.
Wind. A cell is sheltered if a block lies upwind within the assumed multiple of its height. The wind comes from the west. This is a geometric exposure proxy.
Road noise. An ideal line source on the south road gives 68 dB(A) at 10 m, falling by 3 dB per distance doubling. A block across the perpendicular sightline at 1.5 m subtracts the screening allowance. Levels are energy-averaged.
Carbon. Indicative material allowances per m² of element area. Floor structure 240 kgCO₂e, roof 45 kgCO₂e, plus the adjustable external wall factor. The map colours buildings by carbon per m² of floor area. Services, foundations and operation are excluded.