Select a cap in the cutaway to inspect its piles.
Method & limits
The floor spans two bays in each direction. Each column carries its tributary area × the floor load. Each column retains its original four-pile group.
The cap extension encloses the original 2.4 m square and the new 0.5 m column footprint in a convex hull. Added volume equals the extra plan area × 0.8 m depth.
Pile centres form a 1.5 m square. A rigid cap on equal axial springs distributes the column load and its two eccentric moments. Arrows show the force applied by the cap to each pile. Downward is positive compression and upward is negative uplift demand. Arrow direction gives the sign. The labels give the force in kN.
Shafts continue below the cut. Capacity, settlement, cap strength and member self-weight are outside this study. Illustrative.